Recuperator ventilation is a mechanical system that controls air circulation and provides fresh air in rooms. It has several core functions, including expelling foul air. Warm air from outside is passed through advanced filters to remove dirt, dust, and pollen.
Fresh Air Provision: Warm air is supplied with specific parameters, such as temperature, moisture, and efficiency.
Heat & Humidity Recovery: The system recovers heat and humidification from polluted air. These can be used for energy recovery in homes, schools, pharmaceutical industries, and hospitals.
The Energy Recovery Ventilation System will exhaust stale air out of the home and bring fresh air from the outside back in. These two air streams are directed through a highly developed air-to-air energy exchange core, physically separated by many layers of plates to ensure no mixing or contamination of the fresh air.
The unique moisture transfer capability of the ERV core also eliminates condensation and frost build-up in most applications.
| Voltage | 220V/50Hz |
| Max. Air Volume | 600m³/h |
| Rated Air Volume | 350m³/h |
| Rated Power | 130W |
| Net Fresh Air Rate | 98.5% |
| Cooling Enthalpy Efficiency | 67% |
| Heating Enthalpy Efficiency | 72% |
| PM2.5 Filtration Efficiency | 99.8% |
| Heat Pump Cooling Capacity | 3500W |
| Heat Pump Heating Capacity | 4200W |
| Weight | 87kg |