Commercial Energy Efficient 75% Heat Recovery Fresh Air Unit, Air Conditioning System

Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet

Product Description

Basic Info.

Model NO.
HAH
Corrosion Durability
Higher
Operating Voltage
220V, 380-415V, 50/60Hz
Noise Level
Low
Application Fields
Apartment, Office Building, Villa, Industrial
Mounting
Ceiling, Floor Standing
Lifetime
>20 years
Certification
ISO, CE, CCC
Condition
New
Coil Material
Blue Hydrophilic Aluminum Fin/Copper
Tailor Made
Available
OEM/ODM
Available
Capacity
1500-60000 Cfm
Refrigerant
Water
Panel Material
Double Skin with Polyurethane Fitting
Production Capacity
50000 sets

Product Description

Heat Recovery Fresh Air Unit
🌬️WIDE AIR FLOW RANGE

Standardly, ceiling concealed type AHU air flow ranges from 1500 to 15000m3/h; horizontal/vertical type AHU air flow ranges from 2000 to 40000m3/h, able to fulfill various application requirements. Meanwhile, bigger air flow is available by tailor-made as customer special requirement.

🛠️PANEL STRUCTURE DESIGN

Panel is made of powder coated double steel (outer and inner both) with high pressure polyurethane foam fitting in between, thus offering a rigid and robust panel. Frame is made of aluminum alloy which is fastened to the panel, as a result, the unit is strong and lightweight.

🛡️LOW AIR LEAKAGE

Thanks to the high pressure PU foam fitting, and special design insulation method to guarantee no low air leakage, to best minimize loss of energy.

🔇LOW NOISE

Thanks to the rigidly bolted panel, dynamically and statically balanced fan assembly with spring isolator and closely integrated section, maximum to reduce the vibration and noise.

⚙️COIL DESIGN

All coils are designed by professional computer selection software, proved through the lab testing and real life application.

Model Coil Air Flow (m³/h) Fresh Air Condition Return Air Condition Noise dB(A) Weight (kg)
Cooling (kW) Heating (kW) Water Flow (L/S) Resistance (kPa) Cooling (kW) Heating (kW) Water Flow (L/S) Resistance (kPa)
2V/H4ROWS200027.133.21.313.411.222.90.56.756101
3V/H4ROWS300040.554.92.032.617.335.20.816.357128
5V/H4ROWS500068.4102.33.349.528.257.21.424.860176
10V/H6ROWS10000162.8265.38.568.574.5138.03.634.365328
20V/H6ROWS20000331.1463.815.837.8157.4289.27.518.965682
40V/H6ROWS40000615.21015.132.359.3300.9546.014.829.7711265

Facility & Production

Frequently Asked Questions

Q1: What is the typical airflow range of these AHU units?
The units cover a wide range, from 1500 m³/h for ceiling concealed types up to 40,000 m³/h for horizontal or vertical types, with custom capacities reaching up to 60,000 CFM.
Q2: What materials are used for the unit's panel structure?
The panels feature a double-skin design using powder-coated steel with high-pressure polyurethane (PU) foam insulation for maximum thermal efficiency and rigidity.
Q3: How is the noise level kept low during operation?
Low noise is achieved through rigidly bolted panels, statically and dynamically balanced fan assemblies, and the use of spring isolators to minimize vibration.
Q4: What is the expected lifetime of the equipment?
Our AHU units are designed for high durability with a service life exceeding 20 years under proper maintenance conditions.
Q5: Are there options for custom configurations or OEM?
Yes, both tailor-made designs and OEM/ODM services are available to meet specific project requirements and technical specifications.
Q6: What certifications do these units carry?
All units are manufactured to high quality standards and carry ISO, CE, and CCC certifications to ensure international compliance.

Related Products